Receivers

Receiver horizontal BV500/608-1,6 -03

Stamp-welded cylindrical steel receiver for compressed air with a working pressure of 1.6 MPa
Technical specifications
Working pressure (Pw), MPa
1,6
Design pressure (Pd), MPa
1,6
Manufacturing test pressure (Pmt), MPa
Hydraulic
2,2
Pneumatiс
Operating temperature, °C
-20 to +60, °C
Design wall temperature, °C
+60, °C
Minimum permissible negative wall temperature, °С
-20, °C
Name of working medium
air
Nature of the work environment
Work environment group
2
Explosion hazard
Fire hazard
Increase to compensate for corrosion (erosion), mm
0,75
Capacity, l
500,0±10,0
Empty vessel weight, kg
135±15,0
Maximum weight of the medium to be filled, kg
Designated service life of vessel, years
10
Number of loading cycles over the designated service life
103
Vessel group
1
Operating environment group
1
Warranty period – 18 months The Customs Union Certificates

Receiver vertical BV900/810-1,0-16

Stamp-welded cylindrical steel receiver for compressed air with a working pressure of 1.6 MPa
Technical specifications
Working pressure (Pw), MPa
1,0
Design pressure (Pd), MPa
1,0
Manufacturing test pressure (Pmt), MPa
Hydraulic
1,4
Pneumatiс
Operating temperature, °C
-20 to +60, °C
Design wall temperature, °C
+60, °C
Minimum permissible negative wall temperature, °С
-20, °C
Name of working medium
air
Nature of the work environment
Work environment group
2
Explosion hazard
Fire hazard
Increase to compensate for corrosion (erosion), mm
1,5
Capacity, l
900,0±10,0
Empty vessel weight, kg
225±18,0
Maximum weight of the medium to be filled, kg
Designated service life of vessel, years
18
Number of loading cycles over the designated service life
103
Vessel group
1
Operating environment group
2
Warranty period – 18 months The Customs Union Certificates

Receiver vertical BV500/608-1,6 – 50

Stamp-welded cylindrical steel receiver for compressed air with a working pressure of 1.6 MPa
Technical specifications
Working pressure (Pw), MPa
1,6
Design pressure (Pd), MPa
1,6
Manufacturing test pressure (Pmt), MPa
Hydraulic
2,2
Pneumatiс
Operating temperature, °C
-20 to +60, °C
Design wall temperature, °C
+60, °C
Minimum permissible negative wall temperature, °С
-20, °C
Name of working medium
air
Nature of the work environment
Work environment group
2
Explosion hazard
Fire hazard
Increase to compensate for corrosion (erosion), mm
0,75
Capacity, l
500,0±10,0
Empty vessel weight, kg
180±15,0
Maximum weight of the medium to be filled, kg
Designated service life of vessel, years
10
Number of loading cycles over the designated service life
103
Vessel group
1
Operating environment group
1
Warranty period – 18 months The Customs Union Certificates